Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 142
Filtrar
1.
Sci Total Environ ; 891: 164694, 2023 Sep 15.
Artículo en Inglés | MEDLINE | ID: covidwho-20237880

RESUMEN

Since the outbreak of the COVID-19 pandemic, many previous studies using computational fluid dynamics (CFD) have focused on the dynamics of air masses, which are believed to be the carriers of respiratory diseases, in enclosed indoor environments. Although outdoor air may seem to provide smaller exposure risks, it may not necessarily offer adequate ventilation that varies with different micro-climate settings. To comprehensively assess the fluid dynamics in outdoor environments and the efficiency of outdoor ventilation, we simulated the outdoor transmission of a sneeze plume in "hot spots" or areas in which the air is not quickly ventilated. We began by simulating the airflow over buildings at the University of Houston using an OpenFOAM computational fluid dynamics solver that utilized the 2019 seasonal atmospheric velocity profile from an on-site station. Next, we calculated the length of time an existing fluid is replaced by new fresh air in the domain by defining a new variable and selecting the hot spots. Finally, we conducted a large-eddy simulation of a sneeze in outdoor conditions and then simulated a sneeze plume and particles in a hot spot. The results show that fresh incoming air takes as long as 1000 s to ventilate the hot spot area in some specific regions on campus. We also found that even the slightest upward wind causes a sneeze plume to dissipate almost instantaneously at lower elevations. However, downward wind provides a stable condition for the plume, and forward wind can carry a plume even beyond six feet, the recommended social distance for preventing infection. Additionally, the simulation of sneeze droplets shows that the majority of the particles adhered to the ground or body immediately, and airborne particles can be transported more than six feet, even in a minimal amount of ambient air.


Asunto(s)
Contaminación del Aire Interior , COVID-19 , Humanos , Contaminación del Aire Interior/análisis , Pandemias , COVID-19/epidemiología , Simulación por Computador , Viento
3.
Sci Total Environ ; 838(Pt 1): 155884, 2022 Sep 10.
Artículo en Inglés | MEDLINE | ID: covidwho-2328273

RESUMEN

Public health departments such as CDC and California Department of Public Health (CA-DPH) advise HEPA-purifiers to limit transmission of SARS-CoV-2 indoor spaces. CA-DPH recommends air exchanges per hour (ACH) of 4-6 air for rooms with marginal ventilation and 6-12 in classrooms often necessitating multiple HEPA-purifiers per room, unaffordable in under-resourced community settings. Pressure to seek cheap, rapid air filtration resulted in proliferation of lower-cost, Do-It-Yourself (DIY) air purifiers whose performance is not well characterized compared to HEPA-purifiers. Primary metrics are clean air delivery rate (CADR), noise generated (dBA), and affordability ($$). CADR measurement often requires hard-to-replicate laboratory experiments with generated aerosols. We use simplified, low-cost measurement tools of ambient aerosols enabling scalable evaluation of aerosol filtration efficiencies (0.3 to 10 µm), estimated CADR, and noise generation to compare 3 HEPA-purifiers and 9 DIY purifier designs. DIY purifiers consist of one or two box fans coupled to single MERV 13-16 filters (1″-5″ thick) or quad filters in a cube. Accounting for reduced filtration efficiency of MERV 13-16 filters (versus HEPA) at the most penetrating particle size of 0.3 µm, estimated CADR of DIY purifiers using 2″ (67%), 4″ (66%), and 5″ (85%) filters at lowest fan speed was 293 cfm ($35), 322 cfm ($58), and 405 cfm ($120) comparable to best-in-class, low-noise generating HEPA-purifier running at maximum speed with at 282 cfm ($549). Quad filter designs, popularly known Corsi-Rosenthal boxes, achieved gains in estimated CADR below 80% over single filter designs, less than the 100% gain by adding a second DIY purifier. Replacing one of the four filters with a second fan resulted in gains of 125%-150% in estimated CADR. Tested DIY alternatives using lower-efficiency, single filters compare favorably to tested HEPA-purifiers in estimated CADR, noise generated at five to ten times lower cost, enabling cheap, rapid aerosol removal indoors.


Asunto(s)
Filtros de Aire , Contaminación del Aire Interior , COVID-19 , Aerosoles , Contaminación del Aire Interior/análisis , Contaminación del Aire Interior/prevención & control , COVID-19/prevención & control , Polvo , Humanos , Pandemias/prevención & control , SARS-CoV-2
4.
Sci Total Environ ; 891: 164402, 2023 Sep 15.
Artículo en Inglés | MEDLINE | ID: covidwho-2327896

RESUMEN

Over four thousand portable air cleaners (PACs) with high-efficiency particulate air (HEPA) filters were distributed by Public Health - Seattle & King County to homeless shelters during the COVID-19 pandemic. This study aimed to evaluate the real-world effectiveness of these HEPA PACs in reducing indoor particles and understand the factors that affect their use in homeless shelters. Four rooms across three homeless shelters with varying geographic locations and operating conditions were enrolled in this study. At each shelter, multiple PACs were deployed based on the room volume and PAC's clean air delivery rate rating. The energy consumption of these PACs was measured using energy data loggers at 1-min intervals to allow tracking of their use and fan speed for three two-week sampling rounds, separated by single-week gaps, between February and April 2022. Total optical particle number concentration (OPNC) was measured at 2-min intervals at multiple indoor locations and an outdoor ambient location. The empirical indoor and outdoor total OPNC were compared for each site. Additionally, linear mixed-effects regression models (LMERs) were used to assess the relationship between PAC use time and indoor/outdoor total OPNC ratios (I/OOPNC). Based on the LMER models, a 10 % increase in the hourly, daily, and total time PACs were used significantly reduced I/OOPNC by 0.034 [95 % CI: 0.028, 0.040; p < 0.001], 0.051 [95 % CI: 0.020, 0.078; p < 0.001], and 0.252 [95 % CI: 0.150, 0.328; p < 0.001], respectively, indicating that keeping PACs on resulted in significantly lower I/OOPNC. The survey suggested that keeping PACs on and running was the main challenge when operating them in shelters. These findings suggested that HEPA PACs were an effective short-term strategy to reduce indoor particle levels in community congregate living settings during non-wildfire seasons and the need for formulating practical guidance for using them in such an environment.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , COVID-19 , Humanos , Material Particulado/análisis , Contaminación del Aire Interior/prevención & control , Contaminación del Aire Interior/análisis , Washingtón , Pandemias , COVID-19/prevención & control , Polvo , Contaminantes Atmosféricos/análisis
5.
PeerJ ; 11: e15298, 2023.
Artículo en Inglés | MEDLINE | ID: covidwho-2317085

RESUMEN

Background: One of the measures for controlling the coronavirus disease 2019 (COVID-19) pandemic was the mass closure of gyms. This measure leads us to determine the differences between indoor and outdoor air quality. That is why the objective of this study was to analyse the indoor air quality of a sports centre catering to small groups and rehabilitation. Methods: The study was conducted in a single training centre, where 26 measurements were taken in two spaces (indoors and outdoors). The air quality index, temperature, relative humidity, total volatile compounds, carbon monoxide, ozone, formaldehyde, carbon dioxide, and particulate matter were measured indoors and outdoors using the same protocol and equipment. These measurements were taken twice, once in the morning and once in the afternoon, with all measurements made at the same time, 10 am and 6 pm, respectively. Additionally, four determinations of each variable were collected during each shift, and the number of people who had trained in the room and the number of trainers were counted. Results: In the different variables analysed, the results show that CO2 and RH levels are higher indoors than outdoors in both measurement shifts. Temperatures are higher outside than inside and, in the evening, than in the morning. TVOC, AQI and PM show less variation, although they are higher outdoors in the morning. CO is highest indoors. HCHO levels are almost negligible and do not vary significantly, except for a slight increase in the afternoon outside. Ozone levels are not significant. All the variables showed practically perfect reliability in all the measurements, except for ozone measured outside in the morning. On the other hand, the variables exhibit variations between indoors and outdoors during the morning and afternoon, except for the three types of PM. Also, the data show that all the main variables measured inside the sports training centre are similar between morning and afternoon. However, outside, temperature, relative humidity and HCHO levels show significant differences between morning and afternoon while no differences are observed for the other variables. Conclusion: The indoor air quality of the training centre assessed was good and met current regulations; some of its components even exhibited better levels than fresh air. This article is the first to measure indoor air quality in a sports training centre catering to rehabilitation and small groups.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , COVID-19 , Ozono , Humanos , Contaminación del Aire Interior/análisis , Contaminantes Atmosféricos/efectos adversos , Reproducibilidad de los Resultados , COVID-19/epidemiología , Ozono/análisis
6.
Cent Eur J Public Health ; 31(1): 63-68, 2023 03.
Artículo en Inglés | MEDLINE | ID: covidwho-2315403

RESUMEN

OBJECTIVES: Indoor air toxicity is of major public health concern due to the increase in humidity-induced indoor mould exposure and associated health changes. The objective is to present evidence for the causality of health threats and indoor mould exposure. METHODS: PubMed search on the following keywords: dampness, mould, indoor air quality, public health, dampness, and mould hypersensitivity syndrome, sick building syndrome, and building-related illness as well as information from the health authorities of Bavaria and North Rhine-Westphalia, the Center of Disease Control (CDC), World Health Organisation (WHO), and guidelines of professional societies. RESULTS: The guidelines of professional societies published in 2017 are decisive for the assessment of the impact of mould pollution caused by moisture damage on human health and for official regulations in Germany. Until 2017, a causal connection between moisture damage and mould exposure could usually only be established for pulmonary diseases. The health risk of fungal components is apparent as documented in the fungal priority pathogens list (FPPL) of the WHO. Since 2017, studies, especially in Scandinavia, have proved causality between moisture and mould exposure not only for pulmonary diseases but also for extrapulmonary diseases and symptoms. This was made possible by new test methods for determining the toxicity of fungal components in indoor air. Environmental medical syndromes, e.g., dampness and mould hypersensitivity syndrome (DMHS), sick building syndrome (SBS), building-related symptoms (BRS), and building-related illness (BRI), and fungal pathogens, e.g., Aspergillus fumigatus, pose a major threat to public health. CONCLUSION: There is evidence for the causality of moisture-induced indoor moulds and severe health threats in these buildings. According to these findings, it is no longer justifiable to ignore or trivialize the mould contamination induced by moisture damage and its effects on pulmonary and extrapulmonary diseases. The health and economic implications of these attitudes are clear.


Asunto(s)
Contaminación del Aire Interior , Enfermedades Pulmonares , Síndrome del Edificio Enfermo , Cirujanos , Humanos , Contaminación del Aire Interior/efectos adversos , Contaminación del Aire Interior/análisis , Hongos , Humedad
7.
Molecules ; 28(8)2023 Apr 18.
Artículo en Inglés | MEDLINE | ID: covidwho-2304471

RESUMEN

This study aimed to assess the markers of chemical and microbiological contamination of the air at sport centers (e.g., the fitness center in Poland) including the determination of particulate matter, CO2, formaldehyde (DustTrak™ DRX Aerosol Monitor; Multi-functional Air Quality Detector), volatile organic compound (VOC) concentration (headspace solid-phase microextraction coupled with gas chromatography-mass spectrometry), the number of microorganisms in the air (culture methods), and microbial biodiversity (high-throughput sequencing on the Illumina platform). Additionally the number of microorganisms and the presence of SARS-CoV-2 (PCR) on the surfaces was determined. Total particle concentration varied between 0.0445 mg m-3 and 0.0841 mg m-3 with the dominance (99.65-99.99%) of the PM2.5 fraction. The CO2 concentration ranged from 800 ppm to 2198 ppm, while the formaldehyde concentration was from 0.005 mg/m3 to 0.049 mg m-3. A total of 84 VOCs were identified in the air collected from the gym. Phenol, D-limonene, toluene, and 2-ethyl-1-hexanol dominated in the air at the tested facilities. The average daily number of bacteria was 7.17 × 102 CFU m-3-1.68 × 103 CFU m-3, while the number of fungi was 3.03 × 103 CFU m-3-7.34 × 103 CFU m-3. In total, 422 genera of bacteria and 408 genera of fungi representing 21 and 11 phyla, respectively, were detected in the gym. The most abundant bacteria and fungi (>1%) that belonged to the second and third groups of health hazards were: Escherichia-Shigella, Corynebacterium, Bacillus, Staphylococcus, Cladosporium, Aspergillus, and Penicillium. In addition, other species that may be allergenic (Epicoccum) or infectious (Acinetobacter, Sphingomonas, Sporobolomyces) were present in the air. Moreover, the SARS-CoV-2 virus was detected on surfaces in the gym. The monitoring proposal for the assessment of the air quality at a sport center includes the following markers: total particle concentration with the PM2.5 fraction, CO2 concentration, VOCs (phenol, toluene, and 2-ethyl-1-hexanol), and the number of bacteria and fungi.


Asunto(s)
Contaminación del Aire Interior , COVID-19 , Hongos Mitospóricos , Exposición Profesional , Exposición Profesional/análisis , Dióxido de Carbono/análisis , Microbiología del Aire , COVID-19/epidemiología , SARS-CoV-2 , Aerosoles y Gotitas Respiratorias , Hongos , Bacterias , Material Particulado/análisis , Fenoles/análisis , Contaminación del Aire Interior/análisis , Monitoreo del Ambiente
8.
Ecotoxicol Environ Saf ; 256: 114915, 2023 May.
Artículo en Inglés | MEDLINE | ID: covidwho-2302860

RESUMEN

An increase in the concentration of environmental particulate matter and the spread of the COVID-19 virus have dramatically increased our time spent wearing masks. If harmful chemicals are released from these masks, there may be harmful effects on human health. In this study, the concentration of volatile organic compounds (VOCs) emitted from some commonly used masks was assessed qualitatively and quantitatively under diverse conditions (including different mask material types, time between opening the product and wearing, and mask temperature). In KF94 masks, 1-methoxy-2-propanol (221 ± 356 µg m-3), N,N-dimethylacetamide (601 ± 450 µg m-3), n-hexane (268 ± 349 µg m-3), and 2-butanone (160 ± 244 µg m-3) were detected at concentrations 22.9-147 times higher than those found in masks made from other materials, such as cotton and other functional fabrics. In addition, in KF94 masks, the total VOC (TVOC) released amounted to 3730 ± 1331 µg m-3, about 14 times more than that released by the cotton masks (267.5 ± 51.6 µg m-3). In some KF94 masks, TVOC concentration reached over 4000 µg m-3, posing a risk to human health (based on indoor air quality guidelines established by the German Environment Agency). Notably, 30 min after KF94 masks were removed from their packaging, TVOC concentrations decreased by about 80% from their initial levels to 724 ± 5.86 µg m-3; furthermore, 6 h after removal, TVOC concentrations were found to be less than 200 µg m-3. When the temperature of the KF94 masks was raised to 40 oC, TVOC concentrations increased by 119-299%. Since the types and concentrations of VOCs that will be inhaled by mask wearers vary depending on the mask use conditions, it is necessary to comply with safe mask wearing conditions.


Asunto(s)
Contaminación del Aire Interior , COVID-19 , Compuestos Orgánicos Volátiles , Humanos , Compuestos Orgánicos Volátiles/análisis , Máscaras , Contaminación del Aire Interior/análisis , Material Particulado , Monitoreo del Ambiente
9.
Environ Sci Pollut Res Int ; 30(23): 64246-64253, 2023 May.
Artículo en Inglés | MEDLINE | ID: covidwho-2294525

RESUMEN

Formaldehyde has carcinogenic properties. It is associated with nasopharyngeal cancer and causes irritation of the eyes, nose, throat, and respiratory system. Formaldehyde exposure is a significant health concern for those participating in the gross anatomy laboratory, but no learning method can substitute cadaver dissection. We performed a formaldehyde level study in 2018, which found that most of the breathing zone (S-level) and environment (R-level) formaldehyde levels during laboratory sessions at the Faculty of Medicine Siriraj Hospital exceeded international ceiling standards. In the academic year 2019, we adapted the engineering rationale of the NIOSH hierarchy of controls to facilitate formaldehyde clearance by opening the dissection table covers and increasing the area per dissection table, then measured formaldehyde ceiling levels by formaldehyde detector tube with a gas-piston hand pump during (1) body wall, (2) upper limb, (3) head-neck, (4) thorax, (5) spinal cord removal, (6) lower limb, (7) abdomen, and (8) organs of special senses dissection sessions and comparing the results with the 2018 study. The perineum region data were excluded from analyses due to the laboratory closure in 2019 from the COVID-19 outbreak. There were statistically significant differences between the 2018 and 2019 S-levels (p < 0.001) and R-levels (p < 0.001). The mean S-level decreased by 64.18% from 1.34 ± 0.71 to 0.48 ± 0.26 ppm, and the mean R-level decreased by 70.18% from 0.57 ± 0.27 to 0.17 ± 0.09 ppm. The highest formaldehyde level in 2019 was the S-level in the body wall region (1.04 ± 0.3 ppm), followed by the S-level in the abdomen region (0.56 ± 0.08 ppm) and the spinal cord removal region (0.51 ± 0.29 ppm). All 2019 formaldehyde levels passed the OSHA 15-min STEL standard (2 ppm). The R-level in the special sense region (0.06 ± 0.02 ppm) passed the NIOSH 15-min ceiling limit (0.1 ppm). Three levels for 2019 were very close: the R-level in the head-neck region (0.11 ± 0.08 ppm), the abdomen region (0.11 ± 0.08), the body wall region (0.14 ± 0.12 ppm), and the S-level in the special sense region (0.12 ± 0.04 ppm). In summary, extensive analysis and removal of factors impeding formaldehyde clearance can improve the general ventilation system and achieve the OSHA 15-min STEL standard.


Asunto(s)
Contaminación del Aire Interior , COVID-19 , Neoplasias Nasofaríngeas , Exposición Profesional , Humanos , Contaminación del Aire Interior/análisis , Formaldehído/análisis , Docentes , Laboratorios , Exposición Profesional/análisis
10.
Sci Rep ; 13(1): 5735, 2023 04 07.
Artículo en Inglés | MEDLINE | ID: covidwho-2293442

RESUMEN

The COVID-19 pandemic has produced widespread behaviour changes that shifted how people split their time between different environments, altering health risks. Here, we report an update of North American activity patterns before and after pandemic onset, and implications to radioactive radon gas exposure, a leading cause of lung cancer. We surveyed 4009 Canadian households home to people of varied age, gender, employment, community, and income. Whilst overall time spent indoors remained unchanged, time in primary residence increased from 66.4 to 77% of life (+ 1062 h/y) after pandemic onset, increasing annual radiation doses from residential radon by 19.2% (0.97 mSv/y). Disproportionately greater changes were experienced by younger people in newer urban or suburban properties with more occupants, and/or those employed in managerial, administrative, or professional roles excluding medicine. Microinfluencer-based public health messaging stimulated health-seeking behaviour amongst highly impacted, younger groups by > 50%. This work supports re-evaluating environmental health risks modified by still-changing activity patterns.


Asunto(s)
Contaminantes Radiactivos del Aire , Contaminación del Aire Interior , COVID-19 , Neoplasias Pulmonares , Radón , Humanos , Pandemias , Contaminación del Aire Interior/efectos adversos , Contaminación del Aire Interior/análisis , Canadá/epidemiología , Exposición a Riesgos Ambientales/efectos adversos , Exposición a Riesgos Ambientales/análisis , Medición de Riesgo , COVID-19/epidemiología , COVID-19/complicaciones , Radón/toxicidad , Radón/análisis , Contaminantes Radiactivos del Aire/análisis , Neoplasias Pulmonares/epidemiología , Gases
12.
Environ Sci Pollut Res Int ; 30(19): 55278-55297, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: covidwho-2288813

RESUMEN

The transmission of pollutants in buses has an important impact on personal exposure to airborne particles and spread of the COVID-19 epidemic in enclosed spaces. We conducted the following real-time field measurements inside buses: CO2, airborne particle concentration, temperature, and relative humidity data during peak and off-peak hours in spring and autumn. Correlation analysis was adopted to evaluate the dominant factors influencing CO2 and particle mass concentrations in the vehicle. The cumulative personal exposure dose to particulate matter and reproduction number were calculated for passengers on a one-way trip. The results showed the in-cabin CO2 concentrations, with 22.11% and 21.27% of the total time exceeding 1000 ppm in spring and autumn respectively. In-cabin PM2.5 mass concentration exceeded 35 µm/m3 by 57.35% and 86.42% in spring and autumn, respectively. CO2 concentration and the cumulative number of passengers were approximately linearly correlated in both seasons, with R value up to 0.896. The cumulative number of passengers had the most impact on PM2.5 mass concentration among tested parameters. The cumulative personal exposure dose to PM2.5 during a one-way trip in autumn was up to 43.13 µg. The average reproductive number throughout the one-way trip was 0.26; it was 0.57 under the assumed extreme environment. The results of this study provide an important basic theoretical guidance for the optimization of ventilation system design and operation strategies aimed at reducing multi-pollutant integrated health exposure and airborne particle infection (such as SARS-CoV-2) risks.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , COVID-19 , Contaminantes Ambientales , Humanos , Dióxido de Carbono/análisis , SARS-CoV-2 , Aerosoles y Gotitas Respiratorias , Material Particulado/análisis , Contaminantes Atmosféricos/análisis , Vehículos a Motor , China , Contaminantes Ambientales/análisis , Monitoreo del Ambiente/métodos , Contaminación del Aire Interior/análisis , Exposición a Riesgos Ambientales/análisis
14.
Nat Commun ; 14(1): 1332, 2023 03 11.
Artículo en Inglés | MEDLINE | ID: covidwho-2277928

RESUMEN

Currently, the real-life impact of indoor climate, human behaviour, ventilation and air filtration on respiratory pathogen detection and concentration are poorly understood. This hinders the interpretability of bioaerosol quantification in indoor air to surveil respiratory pathogens and transmission risk. We tested 341 indoor air samples from 21 community settings in Belgium for 29 respiratory pathogens using qPCR. On average, 3.9 pathogens were positive per sample and 85.3% of samples tested positive for at least one. Pathogen detection and concentration varied significantly by pathogen, month, and age group in generalised linear (mixed) models and generalised estimating equations. High CO2 and low natural ventilation were independent risk factors for detection. The odds ratio for detection was 1.09 (95% CI 1.03-1.15) per 100 parts per million (ppm) increase in CO2, and 0.88 (95% CI 0.80-0.97) per stepwise increase in natural ventilation (on a Likert scale). CO2 concentration and portable air filtration were independently associated with pathogen concentration. Each 100ppm increase in CO2 was associated with a qPCR Ct value decrease of 0.08 (95% CI -0.12 to -0.04), and portable air filtration with a 0.58 (95% CI 0.25-0.91) increase. The effects of occupancy, sampling duration, mask wearing, vocalisation, temperature, humidity and mechanical ventilation were not significant. Our results support the importance of ventilation and air filtration to reduce transmission.


Asunto(s)
Contaminación del Aire Interior , Humanos , Contaminación del Aire Interior/análisis , Dióxido de Carbono/análisis , Bélgica , Respiración , Oportunidad Relativa , Ventilación/métodos
15.
Sensors (Basel) ; 23(5)2023 Feb 23.
Artículo en Inglés | MEDLINE | ID: covidwho-2285217

RESUMEN

A healthy and safe indoor environment is an important part of containing the coronavirus disease 2019 (COVID-19) pandemic. Therefore, this work presents a real-time Internet of things (IoT) software architecture to automatically calculate and visualize a COVID-19 aerosol transmission risk estimation. This risk estimation is based on indoor climate sensor data, such as carbon dioxide (CO2) and temperature, which is fed into Streaming MASSIF, a semantic stream processing platform, to perform the computations. The results are visualized on a dynamic dashboard that automatically suggests appropriate visualizations based on the semantics of the data. To evaluate the complete architecture, the indoor climate during the student examination periods of January 2020 (pre-COVID) and January 2021 (mid-COVID) was analyzed. When compared to each other, we observe that the COVID-19 measures in 2021 resulted in a safer indoor environment.


Asunto(s)
Contaminación del Aire Interior , COVID-19 , Humanos , Contaminación del Aire Interior/análisis , Aerosoles y Gotitas Respiratorias , Programas Informáticos , Temperatura
16.
Environ Sci Process Impacts ; 25(4): 781-790, 2023 Apr 26.
Artículo en Inglés | MEDLINE | ID: covidwho-2282239

RESUMEN

High levels of reactive chemicals may be emitted to the indoor air during household surface cleaning, leading to poorer air quality and potential health hazards. Hydrogen peroxide (H2O2)-based cleaners have gained popularity in recent years, especially in times of COVID-19. Still, little is known regarding the effects of H2O2 cleaning on indoor air composition. In this work we monitored time-resolved H2O2 concentrations during a cleaning campaign in an occupied single-family residence using a cavity ring-down spectroscopy (CRDS) H2O2 analyzer. During the cleaning experiments, we investigated how unconstrained (i.e., "real-life") surface cleaning with a hydrogen peroxide solution influenced the indoor air quality of the house, and performed controlled experiments to investigate factors that could influence H2O2 levels including surface area and surface material, ventilation, and dwell time of the cleaning solution. Mean peak H2O2 concentrations observed following all surface cleaning events were 135 ppbv. The factors with the greatest effect on H2O2 levels were distance of the cleaned surface from the detector inlet, type of surface cleaned, and solution dwell time.


Asunto(s)
Contaminación del Aire Interior , COVID-19 , Humanos , Peróxido de Hidrógeno , Contaminación del Aire Interior/análisis , Vivienda , Ventilación
17.
J Hosp Infect ; 135: 81-89, 2023 May.
Artículo en Inglés | MEDLINE | ID: covidwho-2253380

RESUMEN

BACKGROUND: Aerosol spread of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) is a major problem in hospitals, leading to an increase in supplementary high-efficiency particulate air filtration aimed at reducing nosocomial transmission. This article reports a natural experiment that occurred when an air cleaning unit (ACU) on a medicine for older people ward was switched off accidentally while being commissioned. AIM: To assess aerosol transport within the ward and determine whether the ACU reduced airborne particulate matter (PM) levels. METHODS: An ACU was placed in a ward comprising two six-bedded bays plus three single-bed isolation rooms which had previously experienced several outbreaks of coronavirus disease 2019. During commissioning, real-time measurements of key indoor air quality parameters (PM1-10, CO2, temperature and humidity) were collected from multiple sensors over 2 days. During this period, the ACU was switched off accidentally for approximately 7 h, allowing the impact of the intervention on PM to be assessed. FINDINGS: The ACU reduced the PM counts considerably (e.g. PM1 65.5-78.2%) throughout the ward (P<0.001 all sizes), with positive correlation found for all PM fractions and CO2 (r=0.343-0.817; all P<0.001). PM counts rose/fell simultaneously when the ACU was off, with correlation of PM signals from multiple locations (e.g. r=0.343-0.868; all P<0.001) for particulates <1 µm). CONCLUSION: Aerosols migrated rapidly between the various ward subcompartments, suggesting that social distancing alone cannot prevent nosocomial transmission of SARS-CoV-2 as this fails to mitigate longer-range (>2 m) transmission. The ACU reduced PM levels considerably throughout the ward space, indicating its potential as an effective intervention to reduce the risk posed by infectious airborne particles.


Asunto(s)
Contaminación del Aire Interior , COVID-19 , Infección Hospitalaria , Humanos , Anciano , Material Particulado/análisis , COVID-19/prevención & control , SARS-CoV-2 , Dióxido de Carbono , Aerosoles y Gotitas Respiratorias , Contaminación del Aire Interior/análisis , Hospitales , Infección Hospitalaria/prevención & control , Reino Unido
18.
Int J Environ Res Public Health ; 19(19)2022 Sep 26.
Artículo en Inglés | MEDLINE | ID: covidwho-2240872

RESUMEN

There is a need to ensure comfortable conditions for hospital staff and patients from the point of view of thermal comfort and air quality so that they do not affect their performance. We consider the need for hospital employees and patients to enjoy conditions of greater well-being during their stay. This is understood as a comfortable thermal sensation and adequate air quality, depending on the task they are performing. The contribution of this article is the formulation of the fundamentals of a system and platform for monitoring thermal comfort and Indoor Air Quality (IAQ) in hospitals, based on an Internet of Things platform composed of a low-cost sensor node network that is capable of measuring critical variables such as humidity, temperature, and Carbon Dioxide (CO2). As part of the platform, a multidimensional data model with an On-Line Analytical Processing (OLAP) approach is presented that offers query flexibility, data volume reduction, as well as a significant reduction in query response times. The experimental results confirm the suitability of the platform's data model, which facilitates operational and strategic decision making in complex hospitals.


Asunto(s)
Contaminación del Aire Interior , Internet de las Cosas , Contaminación del Aire Interior/análisis , Dióxido de Carbono/análisis , Monitoreo del Ambiente/métodos , Hospitales , Humanos , Energía Renovable , Temperatura
19.
Int J Environ Res Public Health ; 20(4)2023 Feb 20.
Artículo en Inglés | MEDLINE | ID: covidwho-2241803

RESUMEN

OBJECTIVES: To review the risk of airborne infections in schools and evaluate the effect of intervention measures reported in field studies. BACKGROUND: Schools are part of a country's critical infrastructure. Good infection prevention measures are essential for reducing the risk of infection in schools as much as possible, since these are places where many individuals spend a great deal of time together every weekday in a small area where airborne pathogens can spread quickly. Appropriate ventilation can reduce the indoor concentration of airborne pathogens and reduce the risk of infection. METHODS: A systematic search of the literature was conducted in the databases Embase, MEDLINE, and ScienceDirect using keywords such as school, classroom, ventilation, carbon dioxide (CO2) concentration, SARS-CoV-2, and airborne transmission. The primary endpoint of the studies selected was the risk of airborne infection or CO2 concentration as a surrogate parameter. Studies were grouped according to the study type. RESULTS: We identified 30 studies that met the inclusion criteria, six of them intervention studies. When specific ventilation strategies were lacking in schools being investigated, CO2 concentrations were often above the recommended maximum values. Improving ventilation lowered the CO2 concentration, resulting in a lower risk of airborne infections. CONCLUSIONS: The ventilation in many schools is not adequate to guarantee good indoor air quality. Ventilation is an important measure for reducing the risk of airborne infections in schools. The most important effect is to reduce the time of residence of pathogens in the classrooms.


Asunto(s)
Contaminación del Aire Interior , COVID-19 , Humanos , SARS-CoV-2 , Dióxido de Carbono/análisis , Respiración , Ventilación/métodos , Instituciones Académicas , Contaminación del Aire Interior/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA